The Invensys License Manager copies the ARCHESTRA.LIC file to the C: Program Files Common Files ArchestrA License folder on the selected computer. Antivirus Software Exclusions After installing Wonderware InTouch HMI Version 11.0, configure your antivirus software to avoid scanning archive files. License: Failed to retrieve information from the FS A2 Development license. Either the FS A2 Development license is not available or it has expired. I checked Invensys Licence Manager and the dev licence is definitely there and its expiry date is June 2017. On the other VM, the licensing setup is identical and ArchestrA IDE opens up with no.
This article offers those who master the classic InTouch R14, a step-by-step instruction on setting up communication with devices using the Modbus TCP protocol. I’ll try to explain those features of the settings that can put a novice developer in a difficult situation.
1. Licensing
The company Klinkmann supports developers of their products, issuing full, but temporary licenses, each of which operates a little less than a month. After the expiration of this period both the development system and runtime stop working. It is required to repeatedly request and update license files.
Usually three files are issued. All of these must be installed in the ArchestrA License Manager. It looks like this:
The absence of a license or an incorrectly installed license may be the cause of the lack of communication. After installing the license, it is desirable to reboot.
2. Download and install the integration package Server DA (DASMBTCP)
Detailed configuration instructions in the video:
3. As an emulator of the MODBUS TCP operation, I usually use the product from Modbus Tools (Modbus Pool & Modbus Slave)
Archestra License Manager 2014 Free
Immediately configure the data exchange to make sure that everything we have is working with the Modbus TCP protocol and data is being exchanged.
Attention!!!
ID is set to 255. Otherwise it will not work. Where to change this value in driver properties – yet did not find. If your Slave device has a different ID, then the working connection will not be achieved.
We disable the Modbus Pool, we do not need the port to be busy at the beginning of the connection.
4. Configure the Server DA driver (DASMBTCP)
Pay attention to the port number (for example, indicated 503)!
Here we form a common list of tags that will exchange data with the PLC
Help describes the signs that we can specify for correct data retrieval
5. Indication of parameters on video frame
We go in WindowMaker
Create an Access Name that will be associated with our topic and server
Next, create the required number of tags associated with the Access Name
Next on the video frame create a dynamic text
Archestra License Manager 2014 Download
Linking (linking) it with the tag we need
6. Run the system Online (Runtime)
If there is no error anywhere, values similar to those in the Modbus Slave
I experimented a bit with disabling the drivers manually. I found out that when communication is lost, the values remain on the screen without changing, without giving out any indication of an error. This is certainly not suitable for the work of the industry. I will look for how to implement otherwise, for example, the replacement of values by the signs of the lattice. I will supplement this article later, when I find a solution
#InTouch, #stepbystep, #instructions, #settings, #drivers, #Modbus, #Stepbystepinstruction, #Stepbystep